PROCEDURES操作

12. If the monitor alarm sounds 如監視器報警:

a. Check the infant immediately.

立即檢查嬰兒;

b. Check the infant"s breathing and color. If the infant is pink but not breathing, wait until the 10th beep before starting stimulation. If the infant is not pink, begin stimulation immediately. Believe observations of the infant before relying on the monitor.

檢查嬰兒呼吸和膚色。如膚色粉紅但無呼吸,等警報器蜂鳴10下後再開始刺激。如嬰兒不是粉紅色,則立即開始刺激。操作時以觀察結果為準,監視器顯示為參考。

13. Use this stimulation sequence: Gently touch the infant; flick the infant"s heel; slap the infant"s foot; rub the infant"s back. (Note: Be certain to teach caregivers never to shake the infant). If the child does not respond, start cardiopulmonary resuscitation (CPR). After the problem resolves, the alarm will stop.

行連續刺激:輕觸嬰兒,指彈嬰兒腳跟,拍擊嬰兒足部,搓擦嬰兒背部(教導護工絕不能搖晃嬰兒)。如無反應,開始心肺復甦。問題解決,告警停止。

14. Press the reset button to turn off the alarm indicator.

按複位鍵關閉告警指示器。

15. Document and report any alarms and nursing responses. Document the infant"s condition. Always note alarm settings when starting and ending any contact with the infant and at least every hour in between.

記錄並報告警報及護理反應。記錄嬰兒病情。在開始和結束與嬰兒接觸時應始終注意警報器設置,每小時不少於一次。